12 research outputs found

    Role of advanced technology in the detection of sight-threatening eye disease in a UK community setting.

    Get PDF
    Background/aims: To determine the performance of combinations of structural and functional screening tests in detecting sight-threatening eye disease in a cohort of elderly subjects recruited from primary care. Methods: 505 subjects aged ≥60 years underwent frequency doubling technology (FDT) perimetry, iVue optical coherence tomography (iWellness and peripapillary retinal nerve fibre layer (RNFL) scans) and intraocular pressure with the Ocular Response Analyzer, all performed by an ophthalmic technician. The reference standard was a full ophthalmic examination by an experienced clinician who was masked to the index test results. Subjects were classified as presence or absence of sight-threatening eye disease (clinically significant cataract, primary open-angle glaucoma, intermediate or advanced age-related macular degeneration and significant diabetic retinopathy). Univariate and multivariate logistic regression analyses were used to determine the association between abnormal screening test results and the presence of sight-threatening eye disease. Results: 171 subjects (33.8%) had one or more sight-threatening eye diseases. The multivariate analysis found significant associations with any of the target conditions for visual acuity of <6/12, an abnormal FDT and peripapillary RNFL thickness outside the 99% normal limit. The sensitivity of this optimised screening panel was 61.3% (95% CI 53.5 to 68.7), with a specificity of 78.8% (95% CI 74.0 to 83.1), a positive predictive value of 59.5% (95% CI 53.7 to 65.2) and an overall diagnostic accuracy of 72.9% (95% CI 68.8 to 76.8). Conclusions: A subset of screening tests may provide an accurate and efficient means of population screening for significant eye disease in the elderly. This study provides useful preliminary data to inform the development of further larger, multicentre screening studies to validate this screening panel

    Noncontact Screening Methods for the Detection of Narrow Anterior Chamber Angles

    Get PDF
    PURPOSE: Comparing diagnostic accuracy of biomicroscope techniques (van Herick and Smith's tests, evaluating limbal and central anterior chamber depth, respectively) and advanced imaging (Visante OCT and Pentacam) for detection of gonioscopically narrow anterior chamber angles (ACAs). METHODS: A total of 78 subjects with narrow or open ACAs underwent four index tests, performed on both eyes by examiners masked to other test results. Diagnostic performance was compared with gonioscopy, using International Society of Geographical and Epidemiological Ophthalmology (ISGEO) definition of primary angle closure and a classification based on clinical opinion of occludability. Data were analyzed using both the eye and the individual as unit of analysis. Sensitivity, specificity, and partial area under the receiver operating characteristic curve (AUROC) were generated. RESULTS: Using the eye as the unit of analysis, the van Herick grading cutoff of 25% or less and ISGEO gonioscopic classification achieved 80% (confidence interval [CI] 65 to 89) sensitivity and 92% specificity (CI 80 to 97) for narrow angle detection, with specificity reaching 97% (CI 87 to 100) for a cutoff of less than or equal to 15%. Notably, with a gonioscopic classification based on clinical opinion of occludability, van Herick (≤25%) together with Smith's test (≤2.50 mm) detected 100% of narrow angle subjects. Of the three Pentacam parameters, anterior chamber volume achieved highest test sensitivity of 85% (CI 70 to 94) using the ISGEO definition. Visante OCT ACA had greatest partial AUROC at 90% specificity, also yielding sensitivity and specificity greater than 85% using the Youden-derived cutoff of less than or equal to 20.7°and ISGEO definition. CONCLUSIONS: Van Herick test and Visante OCT ACA exhibited best discrimination between narrow and open angles both alone, and in combination. Van Herick test affords advantages over Visante OCT, showing potential for identifying individuals who may benefit from further gonioscopic assessment in a case-finding or screening setting

    Predictive value of screening tests for sight-threatening eye disease in a UK population

    Get PDF
    Background/Aims To determine the performance of combinations of structural and functional screening tests in detecting sight-threatening eye disease in a cohort of elderly subjects recruited from primary care Methods 505 subjects ≥ 60 years underwent: Frequency Doubling Technology (FDT) perimetry; iVue OCT (iWellness® and peripapillary retinal nerve fibre layer (RNFL) scans); IOP with the Ocular Response Analyzer (ORA), all performed by an ophthalmic technician. The reference standard was a full ophthalmic examination by an experienced clinician who was masked to the index test results. Subjects were classified as presence or absence of sight-threatening eye disease (clinically significant cataract, primary open angle glaucoma, intermediate or advanced AMD and significant diabetic retinopathy). Univariate and multivariate logistic regression was used to determine the association between abnormal screening test results and the presence of sight-threatening eye disease. Results 171 subjects (33.8%) had one or more sight-threatening eye disease(s). The multivariate analysis found significant associations with any of the target conditions for visual acuity < 6/12, an abnormal FDT and peripapillary RNFL thickness outside the 99% normal limit. The sensitivity of this optimised screening panel was 61.3% (95% CI 53.5-68.7); specificity 78.8% (CI 74.0-83.1), positive predictive value 59.5% (CI 53.7-65.2) and an overall diagnostic accuracy of 72.9% (CI 68.8-76.8). Conclusion A subset of screening tests may provide an accurate and efficient means of population screening for significant eye disease in the elderly. This study provides useful preliminary data to inform the development of further larger, multicentre screening studies to validate this screening panel

    Effect of surgical experience and spine subspecialty on the reliability of the {AO} Spine Upper Cervical Injury Classification System

    Get PDF
    OBJECTIVE The objective of this paper was to determine the interobserver reliability and intraobserver reproducibility of the AO Spine Upper Cervical Injury Classification System based on surgeon experience (&lt; 5 years, 5–10 years, 10–20 years, and &gt; 20 years) and surgical subspecialty (orthopedic spine surgery, neurosurgery, and "other" surgery). METHODS A total of 11,601 assessments of upper cervical spine injuries were evaluated based on the AO Spine Upper Cervical Injury Classification System. Reliability and reproducibility scores were obtained twice, with a 3-week time interval. Descriptive statistics were utilized to examine the percentage of accurately classified injuries, and Pearson’s chi-square or Fisher’s exact test was used to screen for potentially relevant differences between study participants. Kappa coefficients (κ) determined the interobserver reliability and intraobserver reproducibility. RESULTS The intraobserver reproducibility was substantial for surgeon experience level (&lt; 5 years: 0.74 vs 5–10 years: 0.69 vs 10–20 years: 0.69 vs &gt; 20 years: 0.70) and surgical subspecialty (orthopedic spine: 0.71 vs neurosurgery: 0.69 vs other: 0.68). Furthermore, the interobserver reliability was substantial for all surgical experience groups on assessment 1 (&lt; 5 years: 0.67 vs 5–10 years: 0.62 vs 10–20 years: 0.61 vs &gt; 20 years: 0.62), and only surgeons with &gt; 20 years of experience did not have substantial reliability on assessment 2 (&lt; 5 years: 0.62 vs 5–10 years: 0.61 vs 10–20 years: 0.61 vs &gt; 20 years: 0.59). Orthopedic spine surgeons and neurosurgeons had substantial intraobserver reproducibility on both assessment 1 (0.64 vs 0.63) and assessment 2 (0.62 vs 0.63), while other surgeons had moderate reliability on assessment 1 (0.43) and fair reliability on assessment 2 (0.36). CONCLUSIONS The international reliability and reproducibility scores for the AO Spine Upper Cervical Injury Classification System demonstrated substantial intraobserver reproducibility and interobserver reliability regardless of surgical experience and spine subspecialty. These results support the global application of this classification system
    corecore